Kemper System Ltd

Kemperol LF

Manufacturer: Kemper System Ltd 

Materials: Silane Terminated Polyether 

The liquid applied roof waterproofing kit “KEMPEROL LF / KEMPEROL 1K LF” is a kit, which consists of the components:

– Primer “KEMPERTEC EP 5” two component primer based on epoxy resin, fast curing and solvent free
– Fleece “Kemperol 165 fleece” which is a polyester fleece with a grammage of min 148 g/m2
– water proofing membrane “KEMPEROL LF / KEMPEROL 1K LF” based on a single component waterproofing membrane based on SMP, solvent free

For an adequate adhesion of the waterproofing layer – depending on the type of substrate – a primer is required. In general, the primer belonging to the substrate is given in the manufacturer technical documents. In single cases the manufacturer is responsible to give guidance which pre-treatment / primer is required.

The minimum applied layer thickness of the roof waterproofing membrane is 2.7 mm.

As an assembled system these components form a homogeneous seamless roof waterproofing kit.


ETA logo

Number: 20/0404
Issue date: 25/05/2020

Approved for use on


Balconies, Terraces & Walkways Flat Roofs 

For waterproofing complex details, rooflights, drains and gutters and refurbishing small roof projects and balconies.

Substrate


Brick Concrete Copper Fibre Cement Glass Lead Plastic Reinforced Bituminous Membranes Single Ply Membranes - PVC Steel Timber 

KEMPEROL® LF can be applied without a primer directly to plywood, chipboard, OSB, bitumen sheeting (V 13,V 60, G200, PYE (SBS)), plastic elements (PVC-P, PVC-EVA), flexible synthetic sheeting (PVC-P, PVC-EVA), copper, lead, steel, stainless steel, concrete, screed, plaster, fibre cement sheet, bricks, blocks, glass and a range of other substrates (may require an individual adhesion test).

Durability


10 Years 

The verification and assessment methods on which this European Technical Assessment is based lead to the assumption of a working life of the product of at least 10 years.

The indications given on the working life cannot be interpreted as a guarantee given by the producer, but are to be regarded only as a means for choosing the right products in relation to the expected economically reasonable working life of the works.

Installation Requirements


The levels of use categories and the performance of the roof waterproofing can be assumed only, if the installation is carried out according to the installation instructions stated in the technical file of the manufacturer, in particular taking account of the following points:
– installation by appropriately trained personnel,
– installation of only those components which are marked as components of the kit,
– installation with required tools and adjuvants,
– precautions during installation,
– inspecting the roof surface for cleanliness and correct preparation,
– inspecting compliance with suitable weather and curing conditions,
– ensuring a thickness of the waterproofing of at least 2.7 mm by processing of appropriate minimum quantities of material,
– inspections during installation and of the finished product and documentation of the results

Puncture Resistance


P1 - non accessible

Most Compressible Substrate (eg insulation)


P4 - roof gardens, inverted roofs and green roofs)

Least compressible (eg concrete)


Fire Safety


This classification report defines the classification assigned to the roof/roof covering  «Kemperol  LF»  in accordance  with the procedures given in the standard  EN 13501-5:2016  : Fire classification of construction products and building elements – Part 5: Classification using data from external fire exposure to roofs tests: Test 4: Method with two stages incorporating burning brands, wind and supplementary radiant heat.

This classification has been carried out in accordance with clause 9 test 4 of EN 13501-5:2016 and ETAG005-11-08-2000.

The roof / roof covering «Kemperol  LF» in relation to its external fire performance is classified BROOF(t4)

The UK Fire certificate is available in the downloads section.

  • Downloads

Kemper System Ltd

Kemper House
30 Kingsland Grange
Woolston
Warrington
Cheshire
WA1 4RW

T : 01925 445532

E : sales@kempersystem.co.uk

Website disclaimer:

“The information contained in this Website is for general information purposes only. The information is provided by manufacturer members and their accreditation certifications and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with regard to information or products. Any reliance you place on such information is therefore strictly at your own risk.

LRWA Is not an accreditation body and does not test products or have a role in determining whether a product or system is fit for purpose. An agrément certificate is only issued for a successful product or system following a detailed assessment including both laboratory testing and inspections by the certificate provider.”