Kemper System Ltd

Kemperol V210 Roof Waterproofing System

Manufacturer: Kemper System Ltd 

Materials: Flexible Polyesters 

The Kemperol V210 Roof Waterproofing System is a cold liquid-applied, unsaturated polyester coating, reinforced with a 165 g·m–2 embedded polyester fleece to provide a waterproofing membrane with a minimum dry film thickness of 2 mm and typical cured mass of 3.165 Kg·m–2

The system components are:

  • Kemperol V210 — available in two packaging options, a three part V210 system or a two part V210(M) system:
    Kemperol V210
    o Component A — Kemperol V210 Basic Resin
    o Component B — Kemperol V210 Accelerated Resin, containing the required proportion of accelerant
    o Component C — CP Catalyst Powder
    Kemperol V210 M
    o Component M — Kemperol V210 Basic Resin plus Kemperol V210 Accelerated Resin, containing the
    required proportion of accelerant
    o Component C — CP Catalyst Powder
  • Kemperol 165 Fleece — polyester fleece for embedding into Kemperol V210 resin to act as reinforcement. The fleece has nominal characteristics of:
    – weight per unit area (g·m–2) 165 ± 10%
    – tensile strength (N·50 mm–1) ≥ 250
    – elongation at break (%) ≥ 40
    – roll length (m) 50
    – roll width (mm) 105, 210, 262.5, 350, 525, 700 and 1050

BBA logo

Number: 95/3139
Issue date: 12/12/2018

ETA logo

Number: 03/0025
Issue date: 26/04/2017

Approved for use on


Balconies, Terraces & Walkways Biodiverse Brown Roofs Flat Roofs Green Roofs Pitched Roofs Roof Gardens Zero Falls Buried Roofs 

for use as a fully adhered waterproofing layer on pitched, flat and zero fall roofs with limited access. The system is also satisfactory for use as a built-up system on roofs with limited or pedestrian access in:

  • roof gardens (intensive) on flat roofs
  • green roofs (extensive) on flat and pitched roofs
  • biodiverse roofs
  • brown roofs
  • protected terraces/balconies with pedestrian access.

Substrate


Acrylic Glazing Aluminium Brick Concrete Copper Fibre Cement Glass Glass Reinforced Polyester Insulation Boards Lead Mastic Asphalt Metal PUR or PIR Insulation Reinforced Bituminous Membranes Single Ply Membranes - EPDM Single Ply Membranes - PVC Single Ply Membranes - TPO Steel Tiles Timber XPS/PIR Zinc 

When treated with the appropriate primer in accordance with the Certificate holder’s instructions, the system is
suitable for use on substrates of:

  • acrylic glazing
  • aluminium to CP 143-1 : 1958
  • bituminous felts including polymer-modified hot- and cold-applied bitumens and bitumen emulsions
  • liquid bituminous roof coatings
  • concrete and concrete screeds cured sufficiently to achieve the required bond strength
  • copper
  • fibre-reinforced cement sheeting
  • glass
  • GRP
  • lead
  • lightweight concrete
  • mastic asphalt to BS 8218 : 1998
  • polyisocyanurate insulation board (PIR)(1)
  • PVC
  • stainless steel V2A
  • steel to CP 143-10 : 1973
  • tiles (glazed and unglazed)
  • timber, including plywood and orientated strand board (OBS)
  • zinc
  • brickwork, blockwork
  • PVC single-ply membranes
  • TPO single-ply membranes
  • EPDM membranes

(1) The Certificate holder should be consulted for specific advice on board facing compatibility

Durability


25 Years 

With adequate maintenance and repair, the system will have a service life of at least 25 years.

Installation Requirements


Installation of the system must only be carried out by installers trained and approved by the Certificate holder.

Puncture Resistance


P1 - non accessible

Least compressible (eg concrete)


P4 - roof gardens, inverted roofs and green roofs)

Most Compressible Substrate (eg insulation)


Fire Safety


A 19 mm thick plywood deck covered with the system to a thickness of 2 to 2.5 mm will be unrestricted under the national Building Regulations.

The designation of other specifications should be confirmed by: England and Wales — test or assessment in accordance with Approved Document B (Volumes 1 and 2), Appendix A, clause A1, Scotland — test to conform to Mandatory Standard 2.8, clause 2.8.1, Northern Ireland — test or assessment by UKAS-accredited laboratory, or an independent consultant with appropriate experience.

  • Downloads

Kemper System Ltd

Kemper House
30 Kingsland Grange
Woolston
Warrington
Cheshire
WA1 4RW

T : 01925 445532

E : sales@kempersystem.co.uk

Website disclaimer:

“The information contained in this Website is for general information purposes only. The information is provided by manufacturer members and their accreditation certifications and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with regard to information or products. Any reliance you place on such information is therefore strictly at your own risk.

LRWA Is not an accreditation body and does not test products or have a role in determining whether a product or system is fit for purpose. An agrément certificate is only issued for a successful product or system following a detailed assessment including both laboratory testing and inspections by the certificate provider.”