Liquitop system Cold Liquid Applied Roof Waterproofing
Manufacturer: Bauder Limited
Materials: Polyurethane
The Bauder LiquiTOP System Cold Liquid Applied Roof Waterproofing consists of:
• Bauder LiquiTOP PU Mist Grey and Bauder LiquiTOP PU Dark Grey — a single part (moisture triggered) polyurethane
• Bauder LiquiTOP Glass Fibre Mat — for use as system reinforcement
• Bauder LiquiTOP General Purpose Primer — a one-part primer, for preparing exposed bitumen roofing membranes, and porous asphalt, cementitious and timber substrates where required
• Bauder LiquiTOP PVC Primer — a one-part primer, for preparing PVC single-ply membranes prior to application of the embedment coat
• Bauder LiquiTOP Epoxy Primer — a two-part primer for preparing metal substrates
• Bauder LiquiTOP Reactivation Primer — for preparing Bauder LiquiTOP PU left for more than five days and aged areas under repair prior to the application of new coats.
Number: 20/5789 PS1
Issue date: 14/08/2020
Approved for use on
Flat Roofs Pitched Roofs
For use on flat and pitched roofs with limited access.
Substrate
Concrete Insulation Boards Mastic Asphalt Mineral Wool Insulation PUR or PIR Insulation Reinforced Bituminous Membranes Single Ply Membranes - PVC Steel Timber
• concrete
• asphalt
• bituminous roofing membranes, including mineral surfaced
• steel
• PVC membranes
• existing polyurethane coatings
• plywood in conjunction with a specified carrier membrane
• polyisocyanurate (PIR) foam insulation boards in conjunction with a specified carrier membrane
• mineral wool insulation boards in conjunction with a specified carrier membrane.
Durability
20 Years
Under normal service conditions, the system will provide a durable waterproof covering with a service life of at least 20 years.
Installation Requirements
Installation of the Bauder LiquiTOP System Cold Liquid Applied Roof Waterproofing must be carried out only by specialist roofing contractors trained and approved by the Certificate holder, in accordance with the relevant clauses of BS 8000-0 : 2014, BS 8000-4 : 1989, Liquid Roofing and Waterproofing Association (LRWA) Note 7 – Specifier Guidance for Flat Roof Falls the Certificate holder’s instructions and this Certificate
Fire Safety
When classified in accordance with BS EN 13501-5 : 2016, the following systems achieved a BROOF(t4) classification:
• a 18 mm thick orientated strand board (OSB) substrate, a 1.5 mm thick carrier membrane (self-adhesive, foilfaced, modified bitumen), a layer of Bauder LiquiTOP PU applied at 1.0 ℓ·m–2(1.5 kg·m–2) with 225 g·m–2 glass fibre mat embedded and Bauder LiquiTOP PU applied at 1.0 ℓ·m–2(1.5 kg·m–2), tested flat(1)
• a 18 mm thick OSB substrate, 1.5 mm thick air and vapour control layer (AVCL) (self-adhesive, foil-faced, modified bitumen), a bonded 60 mm thick foil-faced polyisocyanurate (PIR) insulation board, a 1.5 mm thick carrier membrane (self-adhesive, foil-faced, modified bitumen), a layer of Bauder LiquiTOP PU applied at 1.0 ℓ·m–2(1.5 kg·m–2) with 225 g·m–2 glass fibre mat embedded and Bauder LiquiTOP PU applied at 1.0 ℓ·m–2 (1.5 kg·m–2), tested flat(1)
• a 18 mm thick OSB substrate, 1.5 mm thick AVCL (self-adhesive, foil-faced, modified bitumen), a bonded 240 mm thick foil-faced PIR insulation board, a 1.5 mm thick carrier membrane (self-adhesive, foil-faced, modified bitumen), a layer of Bauder LiquiTOP PU applied at 1.0 ℓ·m–2 (1.5 kg·m–2) with 225 g·m–2 glass fibre mat embedded and Bauder LiquiTOP PU applied at 1.0 ℓ·m–2 (1.5 kg·m–2), tested flat(1)
• a 18 mm thick OSB substrate, a 1.5 mm thick carrier membrane (self-adhesive, foil-faced, modified bitumen), a layer of Bauder LiquiTOP PU applied at 1.0 ℓ·m–2 (1.5 kg·m–2) with 225 g·m–2 glass fibre mat embedded and Bauder LiquiTOP PU applied at 1.0 ℓ·m–2 (1.5 kg·m–2), tested on a slope(2)
• a 18 mm thick OSB substrate, 1.5 mm thick AVCL (self-adhesive, foil-faced, modified bitumen), a bonded 60 mm thick foil-faced PIR insulation board, a 1.5 mm thick carrier membrane (self-adhesive, foil-faced, modified bitumen), a layer of Bauder LiquiTOP PU applied at 1.0 ℓ·m–2 (1.5 kg·m–2) with 225 g·m–2 glass fibre mat embedded and Bauder LiquiTOP PU applied at 1.0 ℓ·m–2 (1.5 kg·m–2), tested on a slope(2)
• a 18 mm thick OSB substrate, 1.5 mm thick AVCL (self-adhesive, foil-faced, modified bitumen), a bonded 240 mm thick foil-faced PIR insulation board, a 1.5 mm thick carrier membrane (self-adhesive, foil-faced, modified bitumen), a layer of Bauder LiquiTOP PU applied at 1.0 ℓ·m–2 (1.5kg·m–2) with 225 g·m–2 glass fibre mat embedded and Bauder LiquiTOP PU applied at 1.0 ℓ·m–2 (1.5 kg·m–2), tested on a slope(2)
(1) The test is applicable to systems applied to roofs of pitches between 0 to 10°.
(2) The test is applicable to systems applied to roofs of pitches between 10 to 70°.
The designation of other specifications should be confirmed by reference to the requirements of the documents supporting the national Building Regulations.
The system, when used in pitches of greater that 70°, excluding upstands, should not be used on buildings in England and Wales that have a storey at least 18 m above ground level and contain: one or more dwellings, an institution, a room for residential purposes (excluding any room in a hostel, hotel or boarding house), student accommodation, care homes, sheltered housing, hospitals or dormitories in boarding schools.