Moy UK Limited

Paro Melt 2nd Generation Monolithic Hot melt waterproofing system

Manufacturer: Moy UK Limited 

Materials: Hot Applied Polymer Modified Bitumen (Hot Melt) 

The Paro-Melt Second Generation Monolithic Hot Melt Structural Waterproofing is a hot liquid applied, elastomeric bitumen system, forming a seamless membrane with a nominal system thickness of 6 mm. The system consists of:

• Hot Melt Compound — a hot-applied polymer-modified bitumen compound
• Hot Melt Reinforcement Mesh — a polymeric mesh (100g.m-2) for use as the reinforcement layer for the system
• Hot Melt Primer — a surface preparation primer, for use prior to the application of the hot-applied membrane
• Hot Melt Protection Membrane — a polyester reinforced (180 g·m-2) elastomeric SBS modified bitumen, root resistant, waterproofing membrane. The upper and lower surfaces are finished with fine sand
• Hot Melt Detailing Membrane — a stabilised polyester reinforced (180 g·m-2) elastomeric SBS modified bitumen, root resistant, waterproofing membrane. The upper surface is finished with mineral slate chippings and the lower surface with a thermofusible film.


BBA logo

Number: 20/5745 PS1
Issue date: 28/04/2020

Approved for use on


Blue Roofs Brown Roofs Flat Roofs Green Roofs Inverted Roofs Protected Roofs Zero Falls Buried Roofs 

For use as a waterproofing layer on roofs with limited or pedestrian access in:

• inverted roof specifications using aggregate ballast and paving on flat roofs, including zero fall roofs with limited access
• protected roof specifications, eg covered by pavers or other suitable protection on flat roofs, including zero fall roofs
• green roof (extensive), biodiverse roof and brown roof specifications on flat roofs, including zero fall roofs with limited access or pitched roofs with limited access, and roof garden (intensive) specifications
• blue roof specifications in combination with a stormwater attenuation system(1), on flat roofs, including zero fall roofs

(1) The stormwater attenuation system is outside the scope of this Certificate

Substrate


Concrete Metal Timber 

The system is suitable for use on the following substrates:

• in-situ concrete, precast concrete or concrete blocks
• lightweight structural concrete, subject to the Certificate holder’s recommendations
• timber (exterior grade plywood, OSB3, composite timber or sawn timber)
• metal (upstands and flat substrates).

Durability


Design Life of the Roof 

The Paro-Melt Second Generation Monolithic Hot Melt Structural Waterproofing System will provide an effective barrier to the transmission of liquid water and water vapour for the design life of the roof in which it is incorporated.

Installation Requirements


The system should only be installed by trained contractors using specialist equipment. Details of these are available from the Certificate holder.

Fire Safety


In the opinion of the BBA, a roof incorporating the system will be unrestricted under the national Building Regulations in the following circumstances:
• protected or inverted roof specifications, including an inorganic covering listed in the Annex of Commission Decision 2000/553/EC, can be considered to be unrestricted under the national Requirements
• a roof garden covered with a drainage layer of gravel 100 mm thick and a soil layer 300 mm thick
• irrigated roof gardens and green roofs.

The designation of other specifications should be confirmed by reference to the documents supporting the national Building Regulations

The system, when used in pitches of greater that 70°, should not be used on buildings in England and Wales that have a storey at least 18 m above ground level and contain: one or more dwellings, an institution, a room for residential purposes (excluding any room in a hostel, hotel or boarding house), student accommodation, care homes, sheltered housing, hospitals or dormitories in boarding schools.

If allowed to dry, plants used in a roof garden may allow flame spread across the roof. This should be taken into consideration when selecting the plants. Appropriate planting irrigation and/or protection must be applied to ensure the overall fire rating of the roof is not compromised.

  • Downloads

Interested in this product?

Website disclaimer:

“The information contained in this Website is for general information purposes only. The information is provided by manufacturer members and their accreditation certifications and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with regard to information or products. Any reliance you place on such information is therefore strictly at your own risk.

LRWA Is not an accreditation body and does not test products or have a role in determining whether a product or system is fit for purpose. An agrément certificate is only issued for a successful product or system following a detailed assessment including both laboratory testing and inspections by the certificate provider.”