GCP Applied Technologies

Silcor 900HA Roof Waterproofing System

Part of Silcor 900MP Spray Applied Roof Waterproofing System

Manufacturer: GCP Applied Technologies 

Materials: Polyurea 

The Silcor 900HA Roof Waterproofing System comprises Silcor 900HA, a two-component, liquid-applied polyurea membrane, and a range of primers.

The membrane is applied by hand in one coat to provide a waterproofing membrane with a minimum dry film thickness of 2 mm.


BBA logo

Number: 13/5005 PS2
Issue date: 25/07/2019

Approved for use on


Balconies, Terraces & Walkways Inverted Roofs Podium Decks Warm Ballasted Roofs 

For use as a fully adhered waterproofing layer on the following new and existing flat, including those with zero fall, and sloping protected roof specifications including:

  • inverted roofs below extruded polystyrene (XPS) insulation boards
  • ballasted
  • podium decks and covered walkways for pedestrian access
  • terraces

Substrate


Concrete Steel Timber 

The system has been assessed for use on the following substrates:

  • concrete and plywood primed with Primer EPF
  • concrete and plywood with Primer EP LT
  • steel primed with Primer MT.

Durability


25 Years 

Under normal conditions, the system will function effectively as a roof waterproofing for a period in excess of 25 years. In a fully protected specification and when subject to normal service conditions, the system will provide an effective barrier to the transmission of liquid water and water vapour for the design life of the roof in which it is incorporated

Installation Requirements


Installation of the Silcor 900MP Spray-Applied Roof Waterproofing System must be in accordance with the relevant clauses of BS 8000-0 : 2014, BS 8000-4 : 1989, BS 6229 : 2018, the Certificate holder’s instructions and this Certificate.

Installation must not be carried out during inclement weather, eg rain, fog or snow.

Fire Safety


The system, when used in protected or inverted roof specifications, including an inorganic covering listed in the Annex of Commission Decision 2000/553/EC, can enable a roof to be unrestricted under the national Building Regulations.

The designation of other specifications should be confirmed by: England and Wales — test or assessment in accordance with Approved Document B, Appendix A, clause 1, Scotland — test to conform to Mandatory Standard 2.8, clause 2.8.1, Northern Ireland — test or assessment by a UKAS-accredited laboratory or an independent consultant with appropriate experience.


Certified Products

The following products are also covered by the same certification:

  • Downloads

GCP Applied Technologies

580/581 Ipswich Road
Slough
Berkshire
SL1 4EQ

T : 01565 633111

E : SalesOrders.gcp-UK@gcpat.com

Website disclaimer:

“The information contained in this Website is for general information purposes only. The information is provided by manufacturer members and their accreditation certifications and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with regard to information or products. Any reliance you place on such information is therefore strictly at your own risk.

LRWA Is not an accreditation body and does not test products or have a role in determining whether a product or system is fit for purpose. An agrément certificate is only issued for a successful product or system following a detailed assessment including both laboratory testing and inspections by the certificate provider.”